Part Number Hot Search : 
SR240 NTC10 1N5524 CDRH5 4998ET PCI9052G 854917 VP211
Product Description
Full Text Search
 

To Download X3GMC-3050KPGSR Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Pre-amplified/3V Excitation/Gauge
Features
. . . . . 3V excitation, Battery operation available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (X3GMC only)
X3GM-3,X3GM-6 Data sheet
Applications
. Industrial instrumentation . Pressure switch, Pneumatic device . Medical device
Part number for ordering
X3GM C - 3 050KP G S R
Terminal leads direction (See Outline Diagram) R: Rated Pressure (Pa) Model Length of the pressure port X3GM Terminal leads configuration 3 : 3mm S : Surface mount package Available pressure media Pressure type 6 : 6mm No mark : Non-corrosive gas only G : Gauge (Positive pressure) C : Non-corrosive gas and liquid GV : Gauge (Negative pressure) (Contact us about availability) GW : Gauge (Bipolar pressure)
Pressure type X3GM-3 Gauge pressure X3GM-6
Model
Package configuration Measurable pressure range (kPa) 100 100 0 100 0 50 0 100 0 200 0 1000
Surface mount package, 3mm pressure port
Surface mount package, 6mm pressure port
Part number for ordering X3GM-3100KPGWSR X3GM-3100KPGVSR X3GM-3050KPGSR X3GM-3100KPGSR X3GM-3200KPGSR X3GM-3001MPGSR X3GM-6100KPGWSR X3GM-6100KPGVSR X3GM-6050KPGSR X3GM-6100KPGSR X3GM-6200KPGSR X3GM-6001MPGSR
Specifications
Model/Rated pressure 100KPGW 100KPGV 050KPG 100KPG 200KPG 001MPG Unit Recommended operating conditions Pressure type Gauge pressure 100 100 50 100 200 Rated pressure 1.020 1.020 0.510 1.020 2.040 Measurable pressure range 100 100 0 100 0 50 0 100 0 200 Pressure media 1 XFGM : Non-corrosive gas only, XFGMC : Non-corrosive gas and liquid Excitation voltage 3.0 0.15 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 6 Operating temperature 10 80 Storage temperature 20 100 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 ) Current consumption less than 6 Output impedance less than 10 Source current less than 0.1 Sink current less than 1 Mechanical response time 2 (For the reference) Full scale span voltage 1.5 Offset voltage 1.2 0.5 0.075 Full scale span voltage 1.2 2.0 0.075 Accuracy 1.2 5.0
Note ; 1) Please consult us available when you choose the C models. 2) Excluding input voltage error.
1000 10.20 0 1000
kPa kg/cm2 kPa VDC
1.5times of rated pressure VDC
RH mA mA mA msec V V V FS/0 50
1
Pre-amplified/3V Excitation/Gauge
Outline dimensions
X3GM-3,X3GM-6 Data sheet
Unit : mm
X3GM-3
2.54 2.54 Pressure port 1 2 3 0.8
7 6
5 7
4 3
Vent hole
Index 3 0.15 6.5
0.8 10.3
15
MA
X.
0.25
3.5
Recommended footprint for PCB
6 5 4 Labelled faceplate
1.4 1.7 2.54 2.54 9.4
1
1
2
3
Land-pads
(Unit : mm)
Unit : mm
X3GM-6
Pressure port 1
2.54 2.54 0.8 2 3
7 6
5 7
4 3
Vent hole
Index 6 9.5
0.8 10.3
15
MA
Projections
0.5
X.
0.25
3.5
6
5
4
2-R0.5
Recommended footprint for PCB
1.7 1.4 2- 1(Holes for projections) 2.54 2.54 6.0 9.4
1
Projections
1
2
3
Labelled faceplate
Land-pads
(Unit : mm)
2
6.0
Pre-amplified/3V Excitation/Gauge
Connection diagram
X3GM-3,X3GM-6 Data sheet
X3GM-3, X3GM-6
Vcc(DC3V) Vcc
Vout Vout GND C2 C1
Remarks : 1)C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. GND 3)4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other.
Transfer Function
Vout=Vs (P Vs=3.0volts
+ ) (Pressure Error Temperature Error Multiplier
Vs)
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model 050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.01 0.005 0.005 0.0025 0.0025 0.0005 0.005 0.1667 0.1667 0.1667 0.4167 0.1667 0.1667 0.09167 Pressure Error(kPa) 2.5 5.0 5.0 10.0 10.0 50.0 5.0
Temperature Error Multiplier=1
Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : sensor@fujikura.co.jp


▲Up To Search▲   

 
Price & Availability of X3GMC-3050KPGSR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .